DermaSensor

DermaSensor logo
49/ 100

Evidence & Documentation Score

This legacy score reflects documented evidence, integrations, transparency, and market signals. It does not measure overall product performance. A new product-focused rating system is in development. How it is computed

reviewed November 2, 2026

Vendor
DermaSensor, US
Pricing
No published price for an outright purchase. Monthly rental subscription, one-year device use agreement with try-and-return option.
EHR
Not stated
Compliance
FDA De Novo

Bottom line. The FDA granted DermaSensor a De Novo, DEN230008, on January 12, 2024. The handheld probe is held against a lesion a physician already finds suspicious and returns "Monitor" or "Investigate Further" with a score from 1 to 10. It fits a primary care physician deciding whether to refer a lesion. The vendor's own data show that many benign lesions still… Read the full bottom line

Performance profile

  • Regulatory and compliance12 / 22
  • Clinical integration0 / 11.6
  • Evidence strength19.2 / 30
  • Vendor and market9 / 18
  • Sentiment and transparency1.3 / 2.5

Performance profile

  • Regulatory and compliance12 / 22
  • Clinical integration0 / 11.6
  • Evidence strength19.2 / 30
  • Vendor and market9 / 18
  • Sentiment and transparency1.3 / 2.5
On this page

All 10 dimensions

Regulatory and compliance

  • FDA clearance12 / 12

    FDA authorized (1 De Novo grant on record)

  • HIPAA / SOC2 / BAA0 / 10

    No public HIPAA/SOC2/BAA attestation

Clinical integration

  • EHR integrations (count)0 / 5.6

    No EHR integrations listed

  • Top-3 EHR coverage (Epic / Oracle / Athena)0 / 4.8

    None of the top-3 EHRs covered

  • Bidirectional write-back0 / 1.2

    No bidirectional write-back documented

Evidence strength

  • Peer-reviewed papers14.7 / 21

    2 peer-reviewed papers evaluating the product; 1 not counted (product only mentioned or used, or not yet classified)

  • RCT / meta-analysis / systematic review4.5 / 9

    1 observational study (no RCT)

Vendor and market

  • Funding & adoption signal3 / 12

    Seed-stage or unfunded

  • Years in market6 / 6

    Founded 2009 (17 years)

Sentiment and transparency

  • Pricing transparency1.3 / 2.5

    Pricing on request, no public amounts

Computed November 6, 2026 by our public rubric. How it’s computed

What it costs

From
No published price for an outright purchase. Monthly rental subscription, one-year device use agreement with try-and-return option.
Price points
1
Verified
November 2, 2026
Source
Vendor pricing page

All tiers are custom-quoted. The vendor does not publish per-provider list pricing.

TierMonthlyAnnualNotes
EnterpriseNot statedNot statedNo published price for an outright purchase. Monthly rental subscription, one-year device use agreement with try-and-return option.

Source: vendor pricing page. Last checked November 2, 2026.

Compliance

Attested
FDA De Novo
EHR integrations
Not stated
FDA
1 decision on record

Carries FDA De Novo per vendor documentation. Independent attestation review is the buyer's responsibility before clinical deployment.

Vendor stability

Company
DermaSensor
Headquarters
US
Founded
2009

DermaSensor (DermaSensor) was founded in 2009 in US, putting it 17 years into market.

Vendor sitewww.dermasensor.com (opens in new tab)

Evidence record

RecordWhat we found
FDA decisions
Peer-reviewed

3 studies on PubMed: 2 other, 1 observational, published 2024 to 2025. Read the literature summary

Verification
  • Score computed November 6, 2026, method 1.2.1
  • Review written November 2, 2026
Cite this record

MedAI Verdict, DermaSensor record, https://medaiverdict.com/tools/dermasensor, version November 2, 2026

Change historyView every change to this record

Peer-reviewed coverage

PubMed lists 3 papers that name DermaSensor, shown by relevance (title match, study design, recency, journal tier). 2 of them evaluate the product itself; the others only mention it, use it as a tool or do not identify it clearly, and do not count as evidence.

YearJournalTitleAuthors
2024NPJ Digit MedLearnings from the first AI-enabled skin cancer device for primary care authorized by FDA. (opens in new tab)The U.S. Food and Drug Administration’s (FDA) recent authorization of DermaSensor, an AI-enabled device for skin cancer detection in primary care, marks a pivotal moment in digital health innovation. Clinically, the authorization of the first AI-enabled device for use by non-specialists for detecting skin cancer reinforces the feasibility of digital health technologies to bridge gaps in access and expertise in medical practice. The authorization also establishes a new regulatory precedent for FDA authorization of medical devices incorporating AI and machine learning (ML) technologies w…Venkatesh KP, Kadakia KT, Gilbert S
2025J Clin Aesthet DermatolEnhancing Diagnostic Precision in Primary Care: A Multireader Multicase (MRMC) Study of an AI-Powered Handheld Elastic Scattering Spectroscopy Device for Informed Referral Decisions in Melanoma Evaluation. (opens in new tab)Skin cancer is the most common cancer faced by adults in the United States. Melanoma, while a less common subtype of skin cancer compared to basal cell and squamous cell carcinomas, is associated with greater rates of metastases, mortality, and morbidity, and its rate of incidence is projected to increase. Primary care physicians (PCPs) can play an important role in skin cancer detection and in the decision to refer a patient to a dermatologist. Technologies such as the elastic scattering spectroscopy (ESS) device (DermaSensor, Inc.), a handheld, noninvasive assistive tool, may help in the ev…Seiverling EV, Shah A, Weinstock MA, et al.
2025J Prim Care Community HealthObservationalPrimary Care Physician Use of Elastic Scattering Spectroscopy on Skin Lesions Suggestive of Skin Cancer. (opens in new tab)To evaluate the performance of noninvasive, elastic scattering spectroscopy, algorithm-powered device (DermaSensor) to detect melanoma and basal and squamous cell cancers in the primary care setting. DERM-SUCCESS, a blinded, prospective, multicenter pivotal study, enrolled adult patients between August 17, 2020, and December 9, 2021, with lesions that their primary care physicians (PCPs) suspected of skin cancer at clinics in the US (n = 18) and Australia (n = 4). These lesions were assessed by PCPs and scanned with the DermaSensor device. Biopsy specimens were col…Merry SP, Croghan IT, Dukes KA, et al.

See all on PubMed (opens in new tab)

Bottom line

The FDA granted DermaSensor a De Novo, DEN230008, on January 12, 2024. The handheld probe is held against a lesion a physician already finds suspicious and returns "Monitor" or "Investigate Further" with a score from 1 to 10. It fits a primary care physician deciding whether to refer a lesion. The vendor's own data show that many benign lesions still receive "Investigate Further", and the vendor says the device is not a screening tool and not for consumer use.

Handheld spectroscopy device giving primary care physicians an AI score on skin lesions already judged suspicious.

No published price for an outright purchase. Monthly rental subscription, one-year device use agreement with try-and-return option.

What did the FDA decide?

DEN230008 was decided on January 12, 2024 for Dermasensor, Inc., product code QZS, under 21 CFR 878.1830. The classification name is "software-aided adjunctive diagnostic device for use by physicians on lesions suspicious for skin cancer". It is a De Novo classification, so no 510(k) K number exists. The vendor describes use by non-dermatologist physicians on patients 40 and older, and says the result should not be the sole diagnostic criterion.

How does the technology work?

The vendor's technology page describes five spectral recordings per lesion with a xenon lamp across 47 wavelengths, read by a locked algorithm that the vendor says was developed and validated on over 20,000 scans from more than 4,000 malignant and benign lesions. Positive predictive value in vendor data runs from 6% at a score of 1 to 61% at a score of 10.

The FAQ says EHR integration will come "over time". For now a report is uploaded or the result entered manually.

What do the studies report?

The vendor's evidence page presents the figures. In DERM-SUCCESS, a multi-reader, multi-case study in the Journal of Primary Care and Community Health (2025, PMID 40448353), sensitivity was 96% and negative predictive value 97% for a "Monitor" result. Overall specificity was 33% in DERM-ASSESS III, a multicenter prospective blinded melanoma study in JAAD International (2024, PMID 38371666). A prospective evaluation of patient-identified lesions at UPMC (JAAD International 2025, PMID 41048338) is called by the vendor the first independent investigator-initiated US study, and it reports specificity of 9.4% at the lowest cut point.

Company and rental terms

DermaSensor, Inc. is based in Miami and was founded in 2009 by Dr Maurice Ferre and Christopher Dewey. A $16 million Series B on October 2, 2025 brought total investment to $43 million, with new investors Pier 70 Ventures, Kern Venture Group and GenHenn Capital. The vendor claims use in "hundreds of healthcare institutions".

It rents the device by the month under a one-year agreement with a try-and-return option, training included. An outright purchase price is unpublished, no per-scan fee is listed and the FAQ says a dedicated CPT code has not been established.

The verdict

A primary care physician weighing whether to refer is the intended user. A practice whose patients are mostly under 40 falls outside the described use. In the vendor's data, specificity of 9.4% to 33% means many benign lesions receive "Investigate Further".

Editorial review last generated November 2, 2026. Synthesized from clinician sentiment, peer-reviewed coverage, and our editorial silo picks. Refined by hand where vendor facts change.

Link to this review

DermaSensor, reviewed on MedAI Verdict

Vendors may place this badge on their own site. It links to this review with a tracking parameter and has no effect on the score.

<a href="https://medaiverdict.com/tools/dermasensor?utm_source=vendor_badge&utm_medium=badge&utm_campaign=dermasensor"><img src="https://medaiverdict.com/badges/reviewed-on-medaiverdict.png" srcset="https://medaiverdict.com/badges/reviewed-on-medaiverdict@2x.png 2x" alt="DermaSensor, reviewed on MedAI Verdict" width="200" height="56"></a>

What we have not verified

  1. We have not run DermaSensor in our own clinical practice. Pricing, certifications, and EHR-integration claims come from vendor documentation and have not been independently audited.
  2. Enterprise pricing tiers and SLA terms are typically under NDA and not publicly verifiable. Numbers shown reflect publicly disclosed self-service or list pricing only.
  3. Real-world latency, note quality, and accuracy in your specific specialty and patient population can vary materially from vendor demonstrations. We recommend a 30-day trial with two providers before commitment.

Last verified . Read our methodology · Decision support